2. ELECTRICAL CHARACTERISTICS
3. MECHANICAL DATA
4. ENVIROMENTAL TESTS
4.1 GENERAL
After any following test, the response at 1KHz shall not deviate more than ±2dB from the initial value.
4.2 HIGH TEMPERATURE TEST
a. Temperature: +70℃±3℃
b. Duration: 96 hours
c. Duration of recovery: 2 hours
4.3 LOW TEMPERATURE TEST
a. Temperature: -40℃±3℃
b. Duration: 96 hours
c. Duration of recovery: 2 hours
4.4 HUMIDITY TEST
a. Relative humidity: 90-95% at +40℃
b. Duration: 96 hours
c. Duration of recovery: 2 hours
4.5 TEMPERATURE CYCLING TEST
a. Temperature cycling diagram
b. Number of cycles: 4 cycles
c. Duration of recovery

4.6 VIBRATION TEST
a. Vibration direction: 3 axes
b. Frequency: 55 Hz
c. Vibration amplitude: 1.5 mm
d. Duration: 30 minute in each plane
4.7 DROP TEST
a. Unit only: The receiver shall withstand 10 random drops from a height 75cm to a concrete floor, and no mechanical damage.
b. Fixed in handset: The receiver when properly mounted in a handset, shall withstand 6 random drops from a height of 1.5 meters to a concrete floor, and no mechanical damage, and no change the 1KHz response level.