1. SCOPE
This specification covers our product of dynamic receiver unit for mobile telephone use.
2. MECHANICAL LAYOUT & DIMENSIONS
Shown in Fig.5
3. GENERAL REQUIREMENTS
3.1 OPERATING TEMPERATURERANGE: -20℃ ~ +60℃
3.2 STANDARD TEST CONDITIONS:
Temperature: 17~25℃
Relative Humidity:45%~80%(RH)
Air Pressure:860~1060 hPa
3.3 JUDGEMENT CONDITIONS:
Temperature:20±2℃
Relative Humidity:60%~70%(RH)
Air Pressure:860~1060 hPa
4. RECEIVER MODE
4.1 SOUND PRESSURE LEVEL
113±3dB S.P.L. at 1KHz (0dB S.P.L.=20μPa)
Input voltage: 179mV (Sine wave) measured with IEC318 coupler.
4.2 IMPEDANCE: 32±15% Ω(at 1KHz 179mV)
4.3 MEASURING DIAGRAM: Shown in Fig.1
4.4 FREQUENCY RESPONSE MASK & TYPICAL FREQUENCY RESPONSE CURVE:
Shown in Fig.2.
4.5 EARPIECE:Show in Fig.3
4.6 RATED POWER: 10mW.(White noise)
4.7 DISTORTION: <5% THD at 95dB S.P.L. at 300Hz~3400Hz
■ FREQUENCY MEASURING DIAGRAM(RECEIVER MODE)(Fig.1)
■ FREQUENCY RESPONSE MASK & TYPICAL FREQUENCY RESPONSE CURVE(RECEIVER MODE)(Fig.2)
■ EAR PIECE(Fig.3)
5. RELIABILITY TESTS
The sound pressure as specified shall neither deviate more than ±3dB from the initial value, nor any significant damage after any of following testing.
5.1 HIGH TEMPERATURE TEST
High temperature:+70±2℃
Duration:72 hours
5.2 LOW TEMPERATURE TEST
Low temperature:-40±2℃
Duration:72 hours
5.3 HUMIDITY TEST
Temperature:+40±2℃
Relative humidity:90~95%
Duration:96 hours
5.4 TEMPERATURE CYCLE TEST (See in Fig.4)
Temperature:-40℃+70℃
Duration:2 hours2 hours
Cycle:2
5.5 DROP TEST
Mounted with dummy set mass:100 g
Height:1.52 m
Cycle:6 (1 each plain)
onto the concrete board
5.6 LOAD TEST
Receiver mode: White noise (EIA filter) for 96 hours at 10 mW input power.
■ TEMP. CYCLE TEST (Fig.4)
6. DIMENSIONS (Fig.5)

7. PACKING DETAILS (Fig.6)
|